Title: Proposing a validation scheme for 13C metabolite tracer studies in high-resolution mass spectrometry.

Authors: Schwaiger-Haber, Michaela; Hermann, Gerrit; El Abiead, Yasin; Rampler, Evelyn; Wernisch, Stefanie; Sas, Kelli; Pennathur, Subramaniam; Koellensperger, Gunda

Published In Anal Bioanal Chem, (2019 May)

Abstract: 13C metabolite tracer and metabolic flux analyses require upfront experimental planning and validation tools. Here, we present a validation scheme including a comparison of different LC methods that allow for customization of analytical strategies for tracer studies with regard to the targeted metabolites. As the measurement of significant changes in labeling patterns depends on the spectral accuracy, we investigate this aspect comprehensively for high-resolution orbitrap mass spectrometry combined with reversed-phase chromatography, hydrophilic interaction liquid chromatography, or anion-exchange chromatography. Moreover, we propose a quality control protocol based on (1) a metabolite containing selenium to assess the instrument performance and on (2) in vivo synthesized isotopically enriched Pichia pastoris to validate the accuracy of carbon isotopologue distributions (CIDs), in this case considering each isotopologue of a targeted metabolite panel. Finally, validation involved a thorough assessment of procedural blanks and matrix interferences. We compared the analytical figures of merit regarding CID determination for over 40 metabolites between the three methods. Excellent precisions of less than 1% and trueness bias as small as 0.01-1% were found for the majority of compounds, whereas the CID determination of a small fraction was affected by contaminants. For most compounds, changes of labeling pattern as low as 1% could be measured. Graphical abstract.

PubMed ID: 30972471 Exiting the NIEHS site

MeSH Terms: Anion Exchange Resins/chemistry; Carbon Isotopes/analysis*; Carbon Isotopes/standards; Chromatography, Ion Exchange/methods*; Chromatography, Reverse-Phase/methods*; Hydrophobic and Hydrophilic Interactions; Mass Spectrometry/methods*; Pichia/chemistry; Reference Standards; Selenium/chemistry; Validation Studies as Topic*