Skip Navigation

Publication Detail

Title: Kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro.

Authors: Miller, R K; Mattison, D R; Panigel, M; Ceckler, T; Bryant, R; Thomford, P

Published In Environ Health Perspect, (1987 Oct)

Abstract: The transfer and distribution of paramagnetic manganese was investigated in the dually perfused human placenta in vitro (using 10, 20, 100 microM Mn with and without 54Mn) using magnetic resonance imaging (MRI) and conventional radiochemical techniques. The human placenta concentrated 54Mn rapidly during the first 15 min of perfusion and by 4 hr was four times greater than the concentrations of Mn in the maternal perfusate, while the concentration of Mn in the fetal perfusate was 25% of the maternal perfusate levels. Within placentae, 45% of the 54Mn was free in the 100,000g supernatant, with 45% in the 1,000g pellet. The magnetic field dependence of proton nuclear spin-lattice relaxation time (T1) in placental tissue supports this Mn binding. Mn primarily affected the MRI partial saturation rather than spin-echo images of the human placenta, which provided for the separation of perfusate contributions from those produced by Mn. The washout of the Mn from the placenta was slow compared with its uptake, as determined by MRI. Thus, Mn was concentrated by the human placenta, but transfer of Mn across the placenta was limited in either direction. These studies also illustrate the opportunity for studies of human placental function using magnetic resonance imaging as a noninvasive biomarker.

PubMed ID: 3691434 Exiting the NIEHS site

MeSH Terms: No MeSH terms associated with this publication

Back