Skip Navigation

Publication Detail

Title: Endotoxin exposure-response in a fiberglass manufacturing facility.

Authors: Milton, D K; Wypij, D; Kriebel, D; Walters, M D; Hammond, S K; Evans, J S

Published In Am J Ind Med, (1996 Jan)

Abstract: Peak expiratory flow (PEF) and workplace exposure to endotoxin, phenolic resin, and formaldehyde were measured to investigate asthma symptoms and medication use among employees in a fiberglass wool manufacturing plant. Self-recorded PEF was obtained from 37 workers, for a total of 181 days off work and 187 days at work with concurrent personal exposure monitoring. Pre- and post-shift spirometry were obtained on at least 2 days. The 8 hr time-weighted average personal exposure ranges were endotoxin; 0.4-759 ng/m3; phenolic resin, 5.7-327 micrograms/m3; and formaldehyde, 1.2-265 micrograms/m3. Amplitude percent mean peak flow was associated with years since starting regular work in the highest endotoxin exposure area, although current assignment in that area was associated with reduced amplitude--evidence for a healthy worker effect. Exposure-response was analyzed by regression of lung function change on exposure using generalized estimating equations with robust variance estimates. Endotoxin exposure above 4 ng/m3 (8 hr time-weighted average) was associated with a decline in lung function across the work shift, and with drops in lung function 16-20 hr after exposure. Phenolic resin exposure was not consistently associated with decrements, and formaldehyde was not associated with decrements in lung function.

PubMed ID: 8808037 Exiting the NIEHS site

MeSH Terms: No MeSH terms associated with this publication

Back