Skip Navigation
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Your Environment. Your Health.

Publication Detail

Title: Highly selective simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in water samples using microfluidic paper-based analytical devices.

Authors: Kamnoet, Pornphimon; Aeungmaitrepirom, Wanlapa; Menger, Ruth F; Henry, Charles S

Published In Analyst, (2021 Apr 07)

Abstract: A new paper-based analytical device design was fabricated by a wax printing method for simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii). Colorimetry was used to quantify these heavy metal ions using bathocuproine (Bc), dimethylglyoxime (DMG), dithizone (DTZ), and 4-(2-pyridylazo) resorcinol (PAR) as complexing agents. The affinity of complexing agents to heavy metal ions is dependent on the formation constant (Kf). To enhance the selectivity for heavy metal ion determination, the new device was designed with two pretreatment zones, where masking agents remove the interfering ions. It was found that two pretreatment zones worked better than a single pretreatment zone at removing interferences. The reaction time, sample and complexing agent volumes, and complexing agent concentrations were optimized. The analytical results were achieved with the lowest detectable concentrations of 0.32, 0.59, 5.87, 0.20, and 0.11 mg L-1 for Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii), respectively. The linear ranges were found to be 0.32-63.55 mg L-1 (Cu(ii)), 0.59-4.71 mg L-1 (Co(ii)), 5.87-352.16 mg L-1 (Ni(ii)), 0.20-12.04 mg L-1 (Hg(ii)), and 0.11-0.55 mg L-1 (Mn(ii)). The lowest detectable concentration and linearity for the five metal ions allow the application of this device for the determination of heavy metal ions in various water samples. The sensor showed high selectivity and efficiency for simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in drinking, tap, and pond water samples on a single device and detection with the naked eye. The results illustrated that the proposed sensor showed good accuracy and precision agreement with the standard ICP-OES method.

PubMed ID: 33595555 Exiting the NIEHS site

MeSH Terms: No MeSH terms associated with this publication

Back
to Top